A blog of all sections with no images
Medical Gas Certification PDF Print E-mail
Medical Gas Certification 

 

mg.jpg

Medical Gas Certification consists of a comprehensive inspection process using the NFPA 99C Gas and Vacuum Systems Verifications for new construction and renovations.

Air Safe, LLC provides medical gas certifications for healthcare facilities that are being built, renovated, or changing out any equipment to their medical gas systems.  Technicians work intensely with the contractor, engineer, and facilities personnel to make certain the medical gas system is in compliance with current standards and to provide documentation of compliance.  

Any time the medical gas system has been breached it shall be certified by an ASSE 6030 verifier, per NFPA 99C, 2005, 5.1.12.3.


Testing and Inspection of:

•    Medical Gas Source Systems –Bulk, Manifolds, Pumps, and Compressor Systems
•    Outlets, Valves, and Alarms
•    Particulate Analysis
•    Cross-connection and Labeling Verification
•    Flow and Pressure Testing
•    Proper Piping Configuration

 

Medical gas annual verification consists of a comprehensive annual inspection process in accordance with the NFPA 99 Medical Gas Verifications.

The annual inspection for an existing healthcare facility can be performed to verify that the medical gas and vacuum systems throughout the facility are working properly and to identify any safety concerns within the facilities medical gas and vacuum systems.  All inspections are completed using NFPA 99 and ASSE 6000 in order to validate compliance with today’s standards and provide documentation of compliance.

The medical gas piped systems, alarms, and sources should be retested on an annual basis per NFPA 99C, 2005, C.5.2.

 

We can calculate your air change rate using traditional methods as well as more accurately measuring air changes with the use of tracer gas.  This method allows for us to pinpoint problem areas within a room concerning airflows.

 
CTG Notice of Cancellation PDF Print E-mail
 

Air Safe, LLC. Notice of Cancellation of the Containment Technologies Group (CTG) family of isolators (MIC).

 Click above to view the pdf document.

 

Air Safe, LLC. welcomes comments concerning the above topic.  Send comments to:  This e-mail address is being protected from spam bots, you need JavaScript enabled to view it .

 

 
News Feeds PDF Print E-mail
News Feeds Here.
 
HOOD SALE!!! PDF Print E-mail

  Over 20 Hoods discounted for sale NOW! 

 

We have used laminar flow clean benches & biological safety cabinets for sale at extremly reduced prices to move them so our next load can be refurbished.  This is your chance to buy a hood far below the cost of a new unit and at costs well below the average used market prices!

 

Call us at 888-924-7723.  There are only a portion of our hoods listed here on our site.

Many hoods are discounted if purchased prior to May 1, 2010, so hurry!

Here is a sampling of the hoods we have available:

 

 

BAKER EG-6320 LF 6FT
BAKER EG-6252 LF 6FT
BAKER SG-250 BSC 2FT
BAKER B-315 BSC 3FT
BAKER SG-400 BSC 4FT
EACI 10315 LF 6FT
FORMA 1186 BSC 6FT (SOLD)
GERMFREE BBF-3 BSC 3FT
GERMFREE BBF-4SSRX BSC 4FT (SOLD)
NUAIRE NU-425-200 BSC 2FT
NUAIRE NU-425-400 BSC 4FT
NUAIRE NU-440-300 BSC 3FT
NUAIRE NU-425-600 BSC 6FT
NUAIRE NU-201-430 LF 4FT(SOLD)


Call now!

 

 
Clean Bench Certification PDF Print E-mail
Clean Bench Certification 

 

hood02.JPG

The standard Laminar flow hood certification includes air velocity testing to document and obtain an acceptable airflow and calculated total CFM volume, meeting the manufacturer’s specifications.  The HEPA filter integrity test is also performed to document acceptance, no leak in excess of .01% of the upstream challenge concentration.

 

Additional testing includes:  sound level testing, florescent light testing, ultra-violet light testing, electrical testing, vibration testing, particle count classification and temperature testing.

 

All reporting is printed out electronically on-site via computer, and a compliance certificate is issued and applied to the unit denoting test date, status, and re-certification due date.

 

STANDARDS

 

The national standard used by Air Safe to certify the hood's performance is the IES-RP-CC-002.2, Laminar Air Flow Devices, as well as the manufacturer's guidelines.

 

Air Safe provides certification, preventative maintenance, and repairs for all types of hoods as well as other air cleaning and moving equipment:

 

Surgical Suites , TB Rooms, Fume Hoods , Laminar Flow Clean Benches, Biological Safety Cabinets , Isolators, In-Line HEPA systems, Glatt Dryers, Animal Units , Air Showers, HEPA Ovens, BSL-3 Containment Labs, Capture Hoods, Bone Marrow Rooms.

 

Air Safe supports equipment manufactured by:

 

Abatement Technologies, Agnew Higgins, Abbott Laboratories, Air Control, American Scientific, Atmos Tech, Baker Company, Bellco, Bio Quest, BBL, Bio Safe, Bio Clean, Capt Air, Canadian Cabinets, CCI, CCL Classic Modular, Clean Air Products, Clear Air Systems, Dexon, Duralab, EACI, Envirco, Esco, Fisher Scientific, Flow Sciences, Forma Scientific, Gelaire, Germfree Labs, Gruenburg, Hamilton Industries, Hemco, Hoffman, Holten, Howorth Air, HR Inc, I.S.O. Tech Design, Integrated Air Systems, Iroquois, Isle Industries, Johnston Labs, Kendro, Kewaunee Scientific, La Calhene, Lab Products, Labconco, Laminaire, Laminar Flow Inc, Lerner Labs, Lipshaw, MIC, Microviod, Microzone, Modular, Mopec, NuAire, Pureaire Corp, Sci-Med, Sterilaire, St. Charles, Thermo Fisher (Forma) Scientific, Torit, Veco, Weber, Westinghouse, and all forms of manufactured cleanrooms.

 

Air Safe works directly with the manufacturers to provide you with all of your warranty related services for your equipment.

 

Air Safe provides all necessary and required testing to keep your equipment and facility in compliance.

 

Air Flow Velocity & Total Volume, HEPA Filter Leak Test, Lighting, Ultra Violet Lighting, Noise Level, Electrical, Air Flow Smoke Testing, Pressure Testing, Vibration Testing, Particle Count Test, Air Changes.

 

All testing conforms to applicable current test standards, which are denoted on every electronically generated test report.  No handwritten illegible reports from Air Safe.

 

Other Services Provided:

 

Decontamination Services , Filter Repairs & Replacements, Motor Replacements, Electrical Repairs, System Upgrades, Facility exhaust fan PM On-Site Training Programs , and Consulting Services .

 

Air Safe stocks the most commonly needed HEPA filters and blower motors need for repairs. This eliminates the down time associated with equipment being out of service for extended periods.

 

If there is a particular service you are requiring for your equipment please contact Air Safe for additional information.

 

Just because your clean bench is brand new does not mean it is working properly!

 
Cleanroom Cleaning PDF Print E-mail
Cleanroom Cleaning 

 

terra01.jpg

Cleaning your ISO Class 8 or better cleanroom takes more than just your typical housekeeping staff.  There are specific methods and materials which must to be utilized in order to effectively "clean" your cleanroom.  An employee who does not understand the principles on cleanroom housekeeping could negatively impact your facility and potentially jeopardize your product or inadvertently impact patient safety in a hospital setting.

 

Air Safe utilizes the IEST Recommended Practice 018.4 (IEST-RP-CC018.4) Cleanroom Housekeeping:  Operating and Monitoring Procedures as the benchmark for cleanroom cleaning.

 

We can clean and verify the cleaning after it has been completed.  If you need professional properly instituted cleanroom cleaning give us a call for a quote on providing your routine cleaning services.  Proper cleanroom cleaning is just as important as routine cleanroom certifications .

 
<< Start < Prev 1 2 3 4 Next > End >>